Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Pdf is encrypted. Please provide your email address and enter your password to access
We provide PDF for you to look at the catalog, and you need to provide an email address.
Catálogos gratuitos We provide PDF for you to look at the catalog, and you need to provide an email address.
AMC16Z series DC precision power distribution monitoring device Installation and operation instruction
With the rapid development of data centers,the energy consumption of data centers has become more and more prominent. Energy management and power supply and distribution design of data centers have become a hot issue. Efficient and reliable data center power distribution system is an effective way to improve the energy use efficiency of data centers and reduce equipment energy consumption.To realize energy saving of data center,it is necessary to monitor each electrical load first. However,there are many load loops in data center,and traditional measuring instruments cannot meet the requirements of cost,volume,installation,construction and other aspects. Therefore,multi-loop monitoring devices suitable for centralized monitoring of data center are needed. AMC16Z series DC precise distribution monitoring device is a measurement device designed specifically for data center server power management.The device design exquisite,can for A + B two into line and 96 road for electrical parameters,the input and output parameters of the switch state and the lightning protection device such as real-time monitoring,all alarm threshold measurement channels can be set in A separate,to qualify the limit event trigger system sound and light alarm,immediately on the volume in the traditional instrument,the height of the monitoring circuit integration.
AMC16 Series Multi-circuit Monitoring Device for Data Center Installation and Operation Instruction
With the rapid development of data center,the energy consumption problems about the data center have become increasingly serious,and energy management and the design of power supply and distribution have become hot problems;efficient and reliable power distribution system scheme for data center is an effective method to improve the power utilization efficiency of the data center and reduce the energy consumption of equipment. In order to achieve the energy conservation of data center,firstly it is necessary to accurately monitor each electricity load,but there are many loading circuits in the data center,and the traditional measuring instruments are incapable of satisfying the requirements for cost,volume,installation,construction and the like;hence,it is necessary to apply multi-circuit monitoring device applicable to the centralized monitoring requirements of datacenter. AMC16 series multi-circuit monitoring device of Acrel Company is a measuring device designed specifically for the power supply management of server in the data center. Such device is small and exquisite in design,capable of centralized monitoring on various electric parameters and on-off states of dozens of circuits,including incoming line circuit and outgoing line circuit,and it achieves the highly integration of monitoring circuits in volume.
AWT100 Data Conversion Module Installation Manual
At present, wireless technology relies on the advantages of easy deployment, low construction cost, and wide application environment. Data diversification has gradually become an important direction for network development and application in the future industrial Internet. AWT100 data conversion module is a new data conversion DTU launched by Acrel Electric. Communication data conversion includes 2G, 4G, NB, LoRa, LoRaWAN, GPS, WiFi, CE, DP and other communication methods. The downlink interface provides a standard RS485 data interface. It can be easily connected to power meters, RTUs, PLCs, industrial computers and other equipment, and only needs to complete the initial configuration at a time to complete the data collection of the MODBUS equipment; at the same time, the AWT100 series of wireless communication terminals use powerful micro-processing chips to cooperate Built-in watchdog technology, reliable and stable performance.
ANet-2E8S1
ANet-2E8S1 is a general-purpose intelligent communication management machine independently developed by Ankerui Electric Co., Ltd., which is suitable for national public offices, enterprises and institutions, community public institutions, residential commercial buildings, hotel catering and shopping malls, etc. The demand for various forms of electricity, gas, oil, cold, heat and other energy consumption and energy consumption measurement data.
ANet-2E4SM Modular Smart IoT Gateway
ANet-2E4SM Modular Smart IoT Gateway is a general-purpose intelligent communication management machine independently developed by ankerui Electric Co., Ltd. it divides the interface of the traditional management machine into modules that can be assembled and matched. The main module can work independently as a standard intelligent communication management machine. The whole equipment can collect water meters, gas meters, electricity meters through serial ports, Ethernet and other links For the data of microcomputer protection and other equipment terminals, the standard 8-way passive dry contact can collect the switching value information such as access control, flooding and smoke detection in real time, and upload the alarm, real-time data and other information through wired network, 4G network and other links. The master module and slave module can be flexibly expanded to add richer application scenarios. At the same time, they can also provide requirements such as edge computing.
ANet-1E2S1
ANet-1E2S1 is a universal intelligent communication management machine developed by Acrel Electric Co., Ltd., which has Full-Netcom wireless networking function. It is suitable for the national public authorities, enterprises and institutions, public institutions, residential commercial buildings, hotels and restaurants, etc. It can meet the requirements of water, electricity, gas, oil, cooling capacity, heat and other forms of consumption and energy consumption measurement data collection.
ANET 1E2S1-4G
ANet-1E2S1-4G is a universal intelligent communication management machine developed by Acrel Electric Co., Ltd., which has Full-Netcom wireless networking function. It is suitable for the national public authorities, enterprises and institutions, public institutions, residential commercial buildings, hotels and restaurants, etc. It can meet the requirements of water, electricity, gas, oil, cooling capacity, heat and other forms of consumption and energy consumption measurement data collection.
AF-GSM300/400 DTU Data Conversion Module Installation Manual
AF-GSM is a new 4G remote wireless data acquisition device launched by Acrel Electric. By adopting embedded design, it is embedded TCP/IP protocol stack, as well as powerful microprocessor chip and built-in watchdog, therefore, it has reliable and stable performance. In this product, the standard RS485 data interface is provided, which can be easily connected to RTU, PLC, industrial computer and other equipment. It only needs to complete the initial configuration at one time and then it can complete the data acquisition of MODBUS device, and communicates with Acrel server.
AGF-T Perforation type PV confluence acquisition device Installation and Operation Instruction
AGF-T Perforation type PV confluence acquisition device is specially designed for smart PV combiner box. It is used for monitoring the running state of solar panels in solar cell arrays, measuring the currents of solar cell, detecting the state of surge protection devices and DC breaker. The device is equipped with RS485(Modbus) communication port for transmitting all the datas to master device.
External Roche Coil and Switched Transformer Harmonic Meter Installation and operation instruction
The guide-rail harmonic meter with external roche coil and open type mutual inductor is suitable for energy saving renovation projects in high energy consumption industries such as smelting,steel,electric welding,semiconductor,etc.And also for power monitoring of distributed photovoltaic grid-connected cabinet,power demand side management and other applications.The utility model has the advantages of no need to remove primary bus,simple and convenient wiring,safe construction,saving transformation cost and improving efficiency for users.It integrates the measurement of all power parameters(such as current,voltage,active power,reactive power,apparent power,frequency,power factor,etc.),multi-rate electric energy measurement,four-quadrant electric energy measurement,harmonic analysis and electric energy monitoring and assessment management.At the same time, it has a variety of peripheral interface for user to choose:with RS485 communication interface,modbus-rtu protocol can meet the needs of communication network management;The function of [remote signal" and [remote control" of circuit breaker switch can be realized with switch quantity input and relay output.LCD display interface is adoped to realize parameter setting and control through panel keys,which is very suitable for real-time power monitoring system
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.